SIEMENS - 6SE01001AD330AA7
SINAMICS G180 2T2A-07500-200 230-500 V, IT, 50/60 Hz Motor output (typ.) 200kW (500V) HWD without opt. 1060*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3
SIEMENS - 6SE01001AD210AA7
SINAMICS G180 2T2A-07500-005 230-500 V, IT, 50/60 Hz Motor output (typ.) 5.5kW (500V) HWD without opt. 410*165*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3
SIEMENS - 6SE01001AG321AA7
SINAMICS G180 2T2A-07600-200 400-690V TN/TT, 50/60 Hz Motor output (typ.) 200kW (690V) HWD without opt. 1060*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN55011 Class A, First environment C2
SIEMENS - 6SE01001AD248AA7
SINAMICS G180 2T2A-07500-030 230-500 V, IT, 50/60 Hz Motor output (typ.) 30kW (500V) HWD without opt. 610*225*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3
SIEMENS - 6SE01001AC225AA7
SINAMICS G180 2T2A-07400-011 230-500 V, TN/TT 50/60 Hz Motor output (typ.) 11kW (400V) HWD without opt. 510*165*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN 55011 Class A, First environment C2
SIEMENS - 6SE01001AC318AA7
SINAMICS G180 2T2A-07400-090 230-500 V, TN/TT 50/60 Hz Motor output (typ.) 90kW (400V) HWD without opt. 1060*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN55011 Class A, First environment C2
SIEMENS - 6SE01001AG258AA7
SINAMICS G180 2T2A-07600-055 400-690V TN/TT, 50/60 Hz Motor output (typ.) 55kW (690V) HWD without opt. 710*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN55011 Class A, First environment C2
SIEMENS - 6SE01001AG242AA7
SINAMICS G180 2T2A-07600-037 400-690V TN/TT, 50/60 Hz Motor output (typ.) 37kW (690V) HWD without opt. 610*225*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN 55011 Class A, First environment C2
SIEMENS - 6SE01001AG218AA7
SINAMICS G180 2T2A-07600-015 400-690V TN/TT, 50/60 Hz Motor output (typ.) 15kW (690V) HWD without opt. 610*225*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN55011 Class A, First environment C2
SIEMENS - 6SE01001AH234AA7
SINAMICS G180 2T2A-07600-030 400-690V IT, 50/60 Hz Motor output (typ.) 30kW (690V) HWD without opt. 610*225*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3
SIEMENS - 6SE01001AH225AA7
SINAMICS G180 2T2A-07600-022 400-690V IT, 50/60 Hz Motor output (typ.) 22kW (690V) HWD without opt. 610*225*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3
SIEMENS - 6SE01001AG210AA7
SINAMICS G180 2T2A-07600-007 400-690V TN/TT, 50/60 Hz Motor output (typ.) 7.5kW (690V) HWD without opt. 610*225*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN 55011 Class A, First environment C2
SIEMENS - 6SE01001AH321AA7
SINAMICS G180 2T2A-07600-200 400-690V IT, 50/60 Hz Motor output (typ.) 200kW (690V) HWD without opt. 1060*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3
SIEMENS - 6SE01001AC248AA7
SINAMICS G180 2T2A-07400-022 230-500 V, TN/TT 50/60 Hz Motor output (typ.) 22kW (400V) HWD without opt. 610*225*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN55011 Class A, First environment C2
SIEMENS - 6SE01001AH242AA7
SINAMICS G180 2T2A-07600-037 400-690V IT, 50/60 Hz Motor output (typ.) 37kW (690V) HWD without opt. 610*225*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3
SIEMENS - 6SE01001AD321AA7
SINAMICS G180 2T2A-07500-132 230-500 V, IT, 50/60 Hz Motor output (typ.) 132kW (500V) HWD without opt. 1060*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3
SIEMENS - 6SE01001AC155AA7
SINAMICS G180 2T2A-07400-002 230-500V, TN/TT 50/60 Hz Motor output (typ.) 2.2kW (400V) HWD without opt. 410*165*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN55011 Class A, First environment C2
SIEMENS - 6SE01001AC288AA7
SINAMICS G180 2T2A-07400-045 230-500 V, TN/TT 50/60 Hz Motor output (typ.) 45kW (400V) HWD without opt. 710*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN 55011 Class A, First environment C2
SIEMENS - 6SE01001AC315AA7
SINAMICS G180 2T2A-07400-075 230-500 V, TN/TT 50/60 Hz Motor output (typ.) 75kW (400V) HWD without opt. 1060*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN55011 Class A, First environment C2
SIEMENS - 6SE01001AD311AA7
SINAMICS G180 2T2A-07500-075 230-500 V, IT, 50/60 Hz Motor output (typ.) 75kW (500V) HWD without opt. 710*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3