SINAMICS G180 compact units and SINAMICS G180 cabinet systems
Categories
Products
SINAMICS G180 2T2A-07600-110 400-690V IT, 50/60 Hz Motor output (typ.) 110kW (690V) HWD without opt. 1060*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3
SINAMICS G180 2T2A-07500-015 230-500 V, IT, 50/60 Hz Motor output (typ.) 15kW (500V) HWD without opt. 510*165*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3
SINAMICS G180 2T2A-07600-055 400-690V TN/TT, 50/60 Hz Motor output (typ.) 55kW (690V) HWD without opt. 710*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN55011 Class A, First environment C2
SINAMICS G180 2T2A-07500-055 230-500 V, IT, 50/60 Hz Motor output (typ.) 55kW (500V) HWD without opt. 710*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3
SINAMICS G180 2T2A-07500-003 230-500 V, IT, 50/60 Hz Motor output (typ.) 3kW (500V) HWD without opt. 410*165*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3
SINAMICS G180 2T2A-07400-002 230-500V, TN/TT 50/60 Hz Motor output (typ.) 2.2kW (400V) HWD without opt. 410*165*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN55011 Class A, First environment C2
SINAMICS G180 2T2A-07600-200 400-690V TN/TT, 50/60 Hz Motor output (typ.) 200kW (690V) HWD without opt. 1060*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN55011 Class A, First environment C2
SINAMICS G180 2T2A-07500-075 230-500 V, IT, 50/60 Hz Motor output (typ.) 75kW (500V) HWD without opt. 710*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3
SINAMICS G180 2T2A-07600-037 400-690V TN/TT, 50/60 Hz Motor output (typ.) 37kW (690V) HWD without opt. 610*225*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN 55011 Class A, First environment C2
SINAMICS G180 2T2A-07600-110 400-690V TN/TT, 50/60 Hz Motor output (typ.) 110kW (690V) HWD without opt. 1060*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN 55011 Class A, First environment C2
SINAMICS G180 2T2A-07600-007 400-690V TN/TT, 50/60 Hz Motor output (typ.) 7.5kW (690V) HWD without opt. 610*225*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN 55011 Class A, First environment C2
SINAMICS G180 2T2A-07500-132 230-500 V, IT, 50/60 Hz Motor output (typ.) 132kW (500V) HWD without opt. 1060*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3
SINAMICS G180 2T2A-07500-022 230-500 V, IT, 50/60 Hz Motor output (typ.) 22kW (500V) HWD without opt. 610*225*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3
SINAMICS G180 2T2A-07600-160 400-690V TN/TT, 50/60 Hz Motor output (typ.) 160kW (690V) HWD without opt. 1060*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN 55011 Class A, First environment C2
SINAMICS G180 2T2A-07500-037 230-500 V, IT, 50/60 Hz Motor output (typ.) 37kW (500V) HWD without opt. 610*225*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3
SINAMICS G180 2T2A-07600-015 400-690V TN/TT, 50/60 Hz Motor output (typ.) 15kW (690V) HWD without opt. 610*225*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN55011 Class A, First environment C2
SINAMICS G180 2T2A-07500-004 230-500 V, IT, 50/60 Hz Motor output (typ.) 4kW (500V) HWD without opt. 410*165*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3
SINAMICS G180 2T2A-07600-075 400-690V TN/TT, 50/60 Hz Motor output (typ.) 75kW (690V) HWD without opt. 710*350*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN55011 Class A, First environment C2
SINAMICS G180 2T2A-07400-015 230-500 V, TN/TT 50/60 Hz Motor output (typ.) 15kW (400V) HWD without opt. 610*225*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3 line filter EN55011 Class A, First environment C2
SINAMICS G180 2T2A-07500-005 230-500 V, IT, 50/60 Hz Motor output (typ.) 5.5kW (500V) HWD without opt. 410*165*320 mm IP20 air-cooled, 6-pulse line reactor, DV/DT Output filter EMC EN61800-3